Symptom Possible Cause(s) Corrective Action
Tool runs slowly or will not
operate
1. Grit or gum in tool 1. Flush the tool with air tool oil, gum solvent,
or an equal mixture of SAE 10 motor oil
and kerosene. If air tool oil is not used,
lubricate the tool after cleaning
2. No oil in tool 2. Lubricate the tool according to the
lubrication instructions in this manual
3. Low air pressure 3. a. Adjust the regulator on the tool to
the maximum setting
b. Adjust the compressor regulator to tool
maximum while the tool is running
free
4. Air hose leaks* 4. Tighten and seal hose fittings if leaks are
found
5. Pressure drops 5. a. Be sure the hose is the proper size.
Long hoses or tools using large volumes
of air may require a hose with an I.D.
of 1/2 inch or larger depending on the
total length of the hose
b. Do not use a multiple number of hoses
connected together with quick connect
fittings. This causes additional pressure
drops and reduces the tool power.
Directly connect the hoses together
6. Worn ball bearing in motor 6. Remove and inspect bearing for rust, dirt
and grit or worn race. Replace or clean and
regrease bearing with bearing grease
Troubleshooting Chart
Stop using tool immediately if any of the following problems occur. Serious personal injury
could occur. Any repairs or replacements must be done by a Qualified Service Person or
Authorized Service Center.
6
Operating Instructions
www.chpower.com
USER-MAINTENANCE
INSTRUCTIONS
TECHNICAL SERVICE
Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding
the operation or repair of this tool or
for additional copies of this manual.
REPLACEMENT PARTS INFORMATION
For information regarding where to
order replacement parts, call toll free
1-800-543-6400. Please provide the
following information:
•Modelnumber
•Stamped-incode
•Partnumberanddescription
TOOL REPAIR
Only qualified personnel should repair
the tool and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently.
ASSEMBLY PROCEDURE FOR SEALS
When repairing a tool, the internal
parts must be cleaned and lubricated.
Parker O-lube or equivalent must be
used on all o-rings. Each o-ring must be
coated with O-lube before assembling.
A small amount of oil must be used on
all moving surfaces and pivots. After
reassembling, a few drops of 30W
non-detergent oil or equivalent, must
be added through the air line before
testing.
STORAGE
The impact wrench must be lubricated
before storing. Follow the air motor
lubrication instructions with an
exception to step 4. Only run the impact
wrench for 2 to 3 seconds instead of 20
to 30 seconds because more oil needs
to remain in the impact wrench when
storing. The tool should be stored in a
cool dry place.