3. Hold tool upright so nails will slide
backwards toward magazine slot.
(fig. 12)
4. Squeeze the pusher and latch
together to unlatch the pusher
once all nails have been removed.
Adjusting the Nail Penetration
The IFN21950 is equipped with an
adjustable depth of drive feature. This allows the user to determine
how deep a fastener will be driven into the work surface.
1. Adjust the operating pressure to a pressure which will
consistently drive the fasteners. Do not exceed the maximum
operating pressure of the nailer of 120 psi.
2. To adjust the depth-of-drive, loosen the 4mm bolt on the top
of the nose. To increase depth, push WCE in toward nose as
much as desired. Re-tighten bolt
Figure
12 - Unloading fasteners