Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Portable permanently lubricated air
compressors are for home and
workshop use. All models are equipped
with regulators, needle and ball
bearings, and 1725 RPM, 60 Hz motors
with automatic overload protection.
Draining moisture from the air
receivers is required maintenance.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
Unpacking
When unpacking unit, inspect carefully
for any damage that may have occurred
during transit. Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service.
!
NOTICE
!
CAUTION
!
WARNING
!
DANGER
Operating Instructions Home Workshop (FP) Models
Breathable Air Warning
This compressor/pump is not
equipped and should not be used
“as is” to supply breathing
quality air. For any application of
air for human consumption, the
air compressor/pump will need
to be fitted with suitable in-line
safety and alarm equipment. This
additional equipment is
necessary to properly filter and
purify the air to meet minimal
specifications for Grade D
breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of
breathing air application and
proper in-line safety and alarm
equipment is not simultaneously
used, existing warranties shall be
voided, and Campbell Hausfeld
disclaims any liability
whatsoever for any loss,
personal injury or damage.
!
DANGER
Air compressors are utilized in a variety
of air system applications. Because air
compressors and other components
(material pump, spray gun, filters,
lubrications, hoses, etc.) used make up a
high pressure pumping system, the
following safety precautions should be
observed at all times. Only persons well
acquainted with these rules of safe
operation should be allowed to use the
air compressor.
All electrical work
should be done by a
qualified (licensed or certified)
electrician. On a properly wired circuit,
the black wires supply a voltage
potential even when the unit is off.
1. Read instruction manuals for each
component carefully, before
attempting to assemble,
disassemble or operate your
particular system.
2. Do not exceed pressure rating of
any component in system.
3. Protect material lines and air lines
from damage or puncture. Keep
hose and power cable away from
sharp objects, chemical spills, oil,
solvents, and wet floors.
4. Never point a spray gun at oneself
or any other person. Accidental
discharge may result in serious
injury.
5. Check hoses for weak or worn
condition, before each use, making
certain all connections are secure;
do not use if deficiency is found.
Notify an authorized service facility
for examination or repair.
!
WARNING
IN600600AV 9/00
BUILT TO LAST
TM
General Safety
Description
6. Release all pressures within system
slowly; dust and debris may be
harmful.
Disconnect power
and depressurize
system before servicing air compressor!
(Turn pressure regulator knob fully
clockwise after shutting off
compressor).
!
WARNING
© 2000 Campbell Hausfeld
Portable Air Compressors
Compresseurs D’Air Portatifs
Compresores de Aire Portátiles
For parts, product & service information
visit www.chpower.com
Notes
Notas
Home Workshop (FP) Models
Modèles d’atelier Familial (FP)
Modelos (FP) para el Taller y el Hogar
www.chpower.com
Page view 0
1 2 3 4 5 6 ... 18 19

Summary of Contents

Page 1 - Compressors

Portable AirCompressorsPlease read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product

Page 2

pneumatiques ou avant dedébrancher le tuyau.MANOMÈTRE DU RÉSERVOIRLe manomètre indique la pression dansle réservoir ce qui indique que lecompresseur f

Page 3

pneumatiques ou avant dedébrancher le tuyau.MANOMÈTRE DU RÉSERVOIRLe manomètre indique la pression dansle réservoir ce qui indique que lecompresseur f

Page 4

Calibre du Cordon 18 18 14 12 12 10 10 8 8Cordons Prolongateurs Pour Modèle De 120V/5 AmpèresLongueur du Cordon (m) 7,62 15,24 30,48 45,72 60,96 76,2

Page 5

Compresores deAire PortátilesLea con cuidado antes de tratar de armar, instalar, manejar o darle servicio al producto descrito en este manual. Protéja

Page 6

CompresseursD’Air PortatifsS’il vous plaît lire et conserver ces instructions. Lire attentivement avant de monter, installer, utiliser ou de procéder

Page 7

Calibre del cordón 18 18 14 12 12 10 10 8 8Cordones de extensión para los modelos de 120V/5 AmpLongitud del cordón (m) 7,62 15,24 30,48 45,72 60,96 76

Page 8

Home Workshop (FP) Models516 SpCompresores de Aire Portátiles haberlo soltado o si la válvula estáatascada y no la puede activar con elanillo, DEBERA

Page 9

Modelos (FP) para el Taller y el Hogar17 Sp4Portable Air Compressors2. Be sure this gauge reads ZERO beforechanging air tools or disconnecting hosefro

Page 10 - ATTENTION

Gauge of Cord 18 18 14 12 12 10 10 8 8Extension cords for 120V/5 Amp UnitLength of Cord (ft) 25 50 100 150 200 250 300 400 500Home Workshop (FP) Model

Page 11

Modelos (FP) para el Taller y el Hogar19 SpPortable Air Compressors27. Follow all local electrical and safetycodes, as well as the NationalElectrical

Page 12

Modelos (FP) para el Taller y el Hogar19 SpPortable Air Compressors27. Follow all local electrical and safetycodes, as well as the NationalElectrical

Page 13 - Aire Portátiles

Gauge of Cord 18 18 14 12 12 10 10 8 8Extension cords for 120V/5 Amp UnitLength of Cord (ft) 25 50 100 150 200 250 300 400 500Home Workshop (FP) Model

Page 14 - D’Air Portatifs

Modelos (FP) para el Taller y el Hogar17 Sp4Portable Air Compressors2. Be sure this gauge reads ZERO beforechanging air tools or disconnecting hosefro

Page 15 - PRECAUCION

Home Workshop (FP) Models516 SpCompresores de Aire Portátiles haberlo soltado o si la válvula estáatascada y no la puede activar con elanillo, DEBERA

Page 16

Calibre del cordón 18 18 14 12 12 10 10 8 8Cordones de extensión para los modelos de 120V/5 AmpLongitud del cordón (m) 7,62 15,24 30,48 45,72 60,96 76

Page 17 - Operation (Cont.)

CompresseursD’Air PortatifsS’il vous plaît lire et conserver ces instructions. Lire attentivement avant de monter, installer, utiliser ou de procéder

Page 18 - Operation

Compresores deAire PortátilesLea con cuidado antes de tratar de armar, instalar, manejar o darle servicio al producto descrito en este manual. Protéja

Page 19 - Installation

Calibre du Cordon 18 18 14 12 12 10 10 8 8Cordons Prolongateurs Pour Modèle De 120V/5 AmpèresLongueur du Cordon (m) 7,62 15,24 30,48 45,72 60,96 76,2

Comments to this Manuals

No comments