Description
Portable oilless air compressors are for
home and workshop use. Cleaning or
replacement of the inlet filter on all
models and draining moisture from the
air receivers are required maintenance.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not avoided,
WILL result in death or serious injury.
Warning indicates
a potentially
hazardous situation which, if not avoided,
COULD result in death or serious injury.
Caution indicates a
potentially
hazardous situation which, if not avoided,
MAY result in minor or moderate injury.
Notice indicates
important
information, that if not followed, MAY
cause damage to equipment.
Unpacking
When unpacking unit, inspect carefully
for any damage that may have occurred
during transit. Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance. Have the serial number,
model number, and parts list (with
missing parts circled) before calling.
Operating Instructions HM7000 Series, HM7100 Series, HU2000 Series, HU3500 Series
Breathable Air Warning
This compressor/pump is not
equipped and should not be
used “as is” to supply breathing
quality air. For any application of
air for human consumption, the
air compressor/pump will need
to be fitted with suitable in-line
safety and alarm equipment.
This additional equipment is
necessary to properly filter
and purify the air to meet
minimal specifications for Grade
D breathing as described in
Compressed Gas Association
Commodity Specification G
7.1 - 1966, OSHA 29 CFR 1910.
134, and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of breathing
air application and proper in-line
safety and alarm equipment is
not simultaneously used, existing
warranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.
General Safety
CALIFORNIA PROPOSITION 65
This product or
its power cord may
contain chemicals, including lead, known
to the State of California to cause cancer
and birth defects or other reproductive
harm. Wash hands after handling.
You can
create
dust when you cut, sand,
drill or grind materials such
as wood, paint, metal,
concrete, cement, or other
masonry. This dust often contains
chemicals known to cause cancer, birth
defects, or other reproductive harm.
Wear protective gear.
IN632300AV 12/09
GENERAL SAFETY INFORMATION
Air compressors are utilized in a variety
of air system applications. Because air
compressors and other components
(material pump, spray gun, filters,
lubrications, hoses, etc.) used make up
a high pressure pumping system, the
following safety precautions should be
observed at all times. Only persons well
acquainted with these rules of safe
operation should be allowed to use the
air compressor.
All electrical work
should be done by a
qualified (licensed or certified)
electrician. On a properly wired circuit,
the black wires supply a voltage
potential even when the unit is off.
© 2009 Campbell Hausfeld/Scott Fetzer
For parts, product & service information
visit www.chpower.com
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
See Warranty on page 8 for important information about commercial use of this product.
Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.
Model No. ____________________
Serial No. ____________________
Date of purchase _________________
Retain these numbers for future
reference.
STOP!
DO NOT RETURN
THE PRODUCT TO
THE RETAILER!
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Oilless Compressors

Oilless CompressorsPlease read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product des

Page 2 - General Safety (Cont.)

10 FrCompresseurs D’Air Portatifs 1. Lire attentivement tous les manuels d’instructions pour chaque pièce détachée avant d’esssayer de monter, démont

Page 3 - Assembly

Série HM7000, Série HM7100, Série HU2000, Série HU3500 11 Frnettoyage avec des solvants ou produits chimiques toxiques.29. Ne pas fumer pendant la pul

Page 4 - Installation (Cont.)

Seul un électricien qualifié doit effectuer l’installation électrique et raccordements électriques. Respecter toutes les codes locals et national

Page 5 - Operation (Cont.)

13 FrSérie HM7000, Série HM7100, Série HU2000, Série HU3500 • Régulateur - Le régulateur sert à régler la pression d’air à la sortie du tuyau.• Soup

Page 6 - Portable Air Compressors

ENLEVAGE, INSPECTION ET REMPLACEMENT DU FILTREPour remplacer un filtre, enlever le couvercle du carter de filtre. Si l’élément du filtre est sale, tou

Page 7 - Troubleshooting Chart

Guide De Dépannage Symptôme Cause(s) Possible(s) Mesures Correctives1. Perte de puissance ou surchauffage2. Manque de puissance électrique3. Fusibl

Page 8

16 FrCompresseurs D’Air PortatifsGarantie Limitée1. DURÉE: À partir de la date d’achat par l’acheteur original comme suit : Un An.2. GARANTIE ACCORD

Page 9 - Compresseurs

Compresores Sin AceiteLea con cuidado antes de tratar de armar, instalar, manejar o darle servicio al producto descrito en este manual. Protéjase a Ud

Page 10 - Sécurité (Suite)

18 SpCompresores de Aire Portátiles 1. Lea con cuidado todos los manuales incluídos con este producto antes de tratar de ensamblar, desman-telar o u

Page 11 - Installation

Serie HM7000, Serie HM7100, Serie HU2000, Serie HU350019 Sp26. Use un respirador para rociar.27.Nunca rocíe la pintura y otros materiales, directament

Page 12 - Installation (Suite)

Portable Air Compressors2 1. Read instruction manuals for each component carefully, before attempting to assemble, disassemble or operate your partic

Page 13 - Entretien

20 SpCompresores de Aire Portátiles ALAMBRADO1. Los códigos eléctricos varian de un área a otra. Sin embargo el alambrado, enchufe y protectores se

Page 14 - Entretien (Suite)

Figura 5 - Presostato ON/OFFPresostatoReguladorCICLO DE ENCENDIDO/APAGADO DEL COMPRESOREn la posición ON (encendido), el compresor bombea aire dentro

Page 15 - Guide De Dépannage

continúe drenando hasta que la unidad esté vacía.PARA DESMONTAR, CHEQUEAR Y REEMPLAZAR EL FILTROPara cambiarle el filtro quítele la tapa. Saque el fil

Page 16 - Compresseurs D’Air Portatifs

Serie HM7000, Serie HM7100, Serie HU2000, Serie HU350023 SpProblema Posible(s) Causa(s) Acción a Tomar Compresor no funcionaMotor hace ruido pero n

Page 17 - Compresores Sin

Compresores de Aire Portátiles Serie HM7000, Serie HM7100, Serie HU2000, Serie HU3500Garantía Limitada1. DURACION: A partir de la fecha de compra po

Page 18 - Generales de Seguridad

HM7000 Series, HM7100 Series, HU2000 Series, HU3500 Series3AssemblyASSEMBLY TOOLS REQUIREDTools (not provided) for assembly:- (1) 10mm nut driver- (

Page 19 - Instalación

4Portable Air Compressorsbranch circuit.b. Voltage supply is normal.c. Extension cords are of the minimum gauge specified in this instruction manual.d

Page 20 - Instalación (Continuación)

BEFORE FIRST START-UP BREAK-IN PROCEDURE (Complete this procedure before using compressor for the first time. Once completed, it is not necessary to r

Page 21

6www.chpower.comNotesPortable Air Compressors4. Empty the cup, disposing of the water properly.5. If water remains in tank, continue draining until th

Page 22 - Mantenimiento

Symptom Possible Cause(s) Corrective Action1. Loss of power or overheating2. No electrical power3. Blown fuse4. Breaker open5. Thermal overload op

Page 23

8Portable Air Compressorswww.chpower.comLimited Warranty1. DURATION: From the date of purchase by the original purchaser as follows: One Year.2. WHO G